Aircraft Oxygen Systems: Flight Crew, Passenger, and Protective Equipment
General Architecture
Modern transport aircraft typically employ two independent oxygen systems:
- Flight Crew: Gaseous System (High pressure cylinders).
- Passengers: Chemical Oxygen Generators (Solid state) or Gaseous (less common, e.g., some Boeings).
Flight Crew System (Gaseous)
- Source: Oxygen cylinder (usually green).
- Masks: "Quick Donning" type with integrated microphone and regulator.
- Regulator Modes:
- Normal / Diluter Demand (N):
- Delivers a mixture of Cabin Air + Oxygen.
- Ratio increases with cabin altitude.
- Flow: Only on demand (inhalation).
- Auto-100%: Typically switches to 100% automatically above ~35,000 ft.
- 100%:
- Delivers pure oxygen on demand.
- Used if smoke/fumes are suspected or at high altitude.
- Emergency:
- Delivers 100% Oxygen at Positive Pressure.
- Purpose: Prevents ambient smoke/fumes from entering the mask (overpressure pushes out).
- Usage: Fire, Smoke, or Depressurization at very high altitudes.
- Normal / Diluter Demand (N):
- Safety:
- Grease/Oil Hazard: Oxygen accelerates combustion violently. Contact with grease/oil can cause spontaneous combustion/explosion. (Crew must avoid grease-based cosmetics).
Passenger System (Chemical Generators)
- Source: "Chemical Candle" (e.g., Sodium Chlorate).
- Location: PSU (Passenger Service Unit) above seats, Lavatories, Galleys, Crew Stations.
- Deployment:
- Automatic: When cabin altitude exceeds 14,000 - 15,000 ft (CS 25.1447).
- Manual: Switch in cockpit or manual release tool (pin).
- Quantity: Masks must exceed number of seats by at least 10%.
- Operation:
- Activation: Pulling a mask pulls a lanyard/pin, igniting the chemical reaction.
- Flow: Continuous Flow (Constant rate, not demand).
- Duration: 12 to 20 minutes (Typically ~15 min).
- Stop: Cannot be stopped once started.
- Heat: Reaction is exothermic. The canister gets very hot (smell of burning/dust is possible).
- Limitation: Does not protect against smoke/fumes (mixes with generated oxygen).
Protective Breathing Equipment (PBE / Smoke Hood)
- User: Crew members fighting a fire or during evacuation with smoke.
- Function: Protects eyes and respiratory system from toxic gases/smoke.
- Duration: ~15 minutes (Closed circuit chemical regeneration).