Aircraft Oxygen Systems: Flight Crew, Passenger, and Protective Equipment

021-13-01Pablo Asensio Martínez2026-03-272 min

General Architecture

Modern transport aircraft typically employ two independent oxygen systems:

  1. Flight Crew: Gaseous System (High pressure cylinders).
  2. Passengers: Chemical Oxygen Generators (Solid state) or Gaseous (less common, e.g., some Boeings).

Flight Crew System (Gaseous)

  • Source: Oxygen cylinder (usually green).
  • Masks: "Quick Donning" type with integrated microphone and regulator.
  • Regulator Modes:
    1. Normal / Diluter Demand (N):
      • Delivers a mixture of Cabin Air + Oxygen.
      • Ratio increases with cabin altitude.
      • Flow: Only on demand (inhalation).
      • Auto-100%: Typically switches to 100% automatically above ~35,000 ft.
    2. 100%:
      • Delivers pure oxygen on demand.
      • Used if smoke/fumes are suspected or at high altitude.
    3. Emergency:
      • Delivers 100% Oxygen at Positive Pressure.
      • Purpose: Prevents ambient smoke/fumes from entering the mask (overpressure pushes out).
      • Usage: Fire, Smoke, or Depressurization at very high altitudes.
  • Safety:
    • Grease/Oil Hazard: Oxygen accelerates combustion violently. Contact with grease/oil can cause spontaneous combustion/explosion. (Crew must avoid grease-based cosmetics).

Passenger System (Chemical Generators)

  • Source: "Chemical Candle" (e.g., Sodium Chlorate).
  • Location: PSU (Passenger Service Unit) above seats, Lavatories, Galleys, Crew Stations.
  • Deployment:
    • Automatic: When cabin altitude exceeds 14,000 - 15,000 ft (CS 25.1447).
    • Manual: Switch in cockpit or manual release tool (pin).
    • Quantity: Masks must exceed number of seats by at least 10%.
  • Operation:
    • Activation: Pulling a mask pulls a lanyard/pin, igniting the chemical reaction.
    • Flow: Continuous Flow (Constant rate, not demand).
    • Duration: 12 to 20 minutes (Typically ~15 min).
    • Stop: Cannot be stopped once started.
    • Heat: Reaction is exothermic. The canister gets very hot (smell of burning/dust is possible).
  • Limitation: Does not protect against smoke/fumes (mixes with generated oxygen).

Protective Breathing Equipment (PBE / Smoke Hood)

  • User: Crew members fighting a fire or during evacuation with smoke.
  • Function: Protects eyes and respiratory system from toxic gases/smoke.
  • Duration: ~15 minutes (Closed circuit chemical regeneration).
Written and reviewed by

Pablo Asensio

Aeronautical engineer. Passed the thirteen EASA ATPL(A) theoretical knowledge exams studying from these very notes. Writes and reviews each topic against the Part-FCL Learning Objectives.